RH-6033A UL94-2013 Horizontal & Vertical Flammability Test Chamber
The more detailed product information, please click the following links.
http://www.cestr.com/en/product/show.asp?id=213
----------------------
Our coustomer
Currently use more than 100 customers, mainly include: UL lab in Hong Kong, UL meihua, Taiwan yi sheng group (Taiwan)/shenzhen/kunshan/Vietnam, Taiwan longwell (shenzhen/suzhou), Taiwan have a good group (shenzhen jf/foothills of suzhou), Taiwan instrument (shenzhen/Shanghai), Shanghai zhou electric utility, shenzhen Wen Wei plastic, cooper d xi (kunshan Wells) in Taiwan, dongguan rong tai plastic, shenzhen crown, shenzhen/suzhou rl, dow chemical, polymer, Shanghai branch teng chang-rong li chemical industry in Taiwan, foshan KaiHua electric industry, Hong Kong and rich plastic group (shenzhen branch makes baycom/ningbo and shenzhen), Taiwan daxing wires, shenzhen gwangju electric utility, taishan, wires, formal wire dongguan, dongguan everwood, dongguan cable, dongguan yongli electric utility, shenzhen crown wires, dongguan tong yuan, three friends live in suzhou, dongguan wanfeng wire, dongguan frequently on photoelectric co., Ltd, Japan cane warehouse (Thailand) factory Fujikura Electronics (Thailand) Ltd, Hong Kong constant group/constant wire (shenzhen) co., Ltd., German lenny electric cables (changzhou) co., Ltd., ningbo green lake elastomer material technology co., Ltd., Hong Kong rose glow wire and cable (shenzhen) co., Ltd., dongguan big fellow electric factory, huzhou long ding Electronics co., Ltd., xintai (dongguan city tai), Taiwan letter yu...
RH-6033 UL wire combustion chamber meet the standard:
RH-6033 UL wire and combustion chamber http://www.cestr.com/cn/product/show.asp?id=179, http://www.cestr.com.cn/html/cn/pro/ranshaoshiyanji/20121213/5.html
UL 2556-2011(UL 1581-2011 ), UL 94-2012,ASTM D5025-2005,ASTM D5207-2009.
RH-6033A UL94 Vertical burning test sheet or strip 5 va or vb RH-6033A UL94-2012 thin material vertical burning test http://www.cestr.com/cn/product/show.asp?id=213, http://www.cestr.com.cn/html/cn/pro/ranshaoshiyanji/20121213/4.html
Vertical level of the combustion chamber UL94HB:
ASTM D 635, IEC 60695-11-10 (原ISO 1210) & GB/T 5169.16 Test method for.
The vertical burning test UL 94 V-0, V-1, 或 V-2:
ASTM D 3801, IEC 60695-11-10 (原ISO 1210) & GB/T 5169.16 test method,IEC 60707 section).
500W (125mm) vertical burning test sheet or strip 5VA or 5VB:
ASTM D 5048, IEC 60695-11-20 (原ISO 10351) & GB/T 5169.17 test ways , IEC 60707, ISO 9772.
thin material vertical combustion test VTM-0, VTM-1 or VTM-2:ASTM D 4804, ISO 9773
standard foam material combustion test,HF- 1, HF-2 or HBF:ASTM D 4986, ISO 9772.3.
Bunsen burner(burner):ASTM D5025-2005,ASTM D5207-2009, ISO 10093.
|
Extract exclusive-combustion chamber requirements and standarda,UL wire test experience sharing and summary:
|
UL wire order combustion chamber of the standards and technical tequirements:http://www.cestr.com/cn/news/show.asp?id=214
|
UL wire combustion chamber using problem summary:http://www.cestr.com/cn/news/show.asp?id=210
|
UL wire combustion chamber attention and safety requirements:http://www.cestr.com/cn/news/show.asp?id=209
|
UL1581/UL2556 wire VW-1 fire test operation method:http://www.cestr.com/cn/news/show.asp?id=200
|
UL1581/UL2556 wire FT1 combustion test operation method
:http://www.cestr.com/cn/news/show.asp?id=199
|
UL2556/UL1581/UL94/UL1666/UL62/817/444 combustion test operation method
http://www.cestr.com/cn/news/show.asp?id=195
|
UL758-2010 combustion performance test
:http://www.cestr.com/cn/news/show.asp?id=197
|
ASTM D5207-2009 20 mm (50-W)和125mm(500-W) Flame test validation procedures:http://www.cestr.com/cn/news/show.asp?id=194
|
Humboldt the Americal hamburger ladder riel ASTM D5025標準H5025噴燈(燃燒器/本生燈):http://www.cestr.com/cn/news/show.asp?id=190
|
Combustion chamber gas leak detection methods and attention:http://www.cestr.com/cn/news/show.asp?id=178
|
UL94-2012 burning test method and experience sharing:http://www.cestr.com/cn/news/show.asp?id=163
|
UL94 level vertical combustion chamber right rational selection and evaluation:http://www.cestr.com/cn/news/show.asp?id=79
|
wire fire performance standards, CSA-FT1,CSA-FT4,UL910,UL1666,IEC/EN60811 flame retardant grade:http://www.cestr.com/cn/news/show.asp?id=73
|
UL2556-2011(UL2556 chinese version) wire burning printing requirements(FT1, FT2, FT4, FT6,VW-1 grade differenve distinct,UL/CSA wire burning mark recognition,the fire resistant rating than gauge wire:http://www.cestr.com/cn/news/show.asp?id=53
|
UL94 Electronic products,plastic modified flame retardnt specification 2013-10(October 23, 2012),FPC PCB V and VTM testing important differences,UL 94 VTM test file revier (plastic flame retardancy standard modify): http://www.cestr.com/cn/news/show.asp?id=55
|
UL2556 Chinese version download:http://www.cestr.com/cn/support/down.asp
|
|